2014-10-10 04:00:59 | Lượt xem: 2736 | Energy and greenhouse gases
How a BMS brings together monitoring, alarms, scheduling and authorized control of a building’s technical systems.
ITVC GLOBAL · KNOWLEDGE AND NEWS
A building management system (BMS) collects technical information and coordinates selected building services through a central interface. Its scope depends on the building, equipment and agreed integration design.

Integration with a life-safety system must preserve its required independent functions and approved control priorities. A BMS does not automatically replace a dedicated fire alarm or safety controller.
The BMS can collect environmental measurements, equipment status and system operating information. Data storage, trend processing and retention periods are defined by the project and management needs.
A graphical interface presents technical alarms and equipment faults. Audible alerts can draw an operator’s attention to conditions requiring a response. Alarm priorities, acknowledgement and escalation should be configured for the building’s operations.
Authorized operators may control supported points through equipment graphics or floor plans. Schedules can coordinate operation with daily, weekly or longer-term building needs and help reduce unnecessary energy use.
Changes to schedules and control commands should be made within the permitted operating limits. Available commands depend on the connected equipment and integration design.
Operators can be assigned different monitoring and control permissions according to their responsibilities. Logs record access and actions, helping the management team investigate changes and operating events.
The BMS design includes two servers, automatic backup and distributed building controllers connected through a LAN. Redundancy, failover and backup are project features that must be specified and tested; they are not guaranteed in every BMS.
Controllers may retain programmes, parameters and trend data during particular interruptions, subject to their memory, power arrangements and configuration. Local operation during a network outage also depends on the designed access method and controller capabilities.
Interfaces such as BACnet and Modbus can connect compatible systems. Controllers are commonly located near the plant they serve, such as electrical rooms or HVAC equipment rooms.
Define the points list, operating sequences, alarm strategy, access permissions, data retention and failure response before implementation. Proper commissioning and operator training help turn integrated information into more effective building management and better control of operating costs.
ITVC GLOBAL · SERVICE ENQUIRIES
Share your requirements and preferred timing. ITVC will review your enquiry and discuss a suitable service scope.
Hotline: 0914 564 579
Ho Chi Minh City: 0859 553 986
Email: itvc.haiphong@itvc-global.com
Head office: 6th Floor, 22 Ly Tu Trong, Hong Bang Ward, Hai Phong, Vietnam.
Dịch vụ của chúng tôi
Tin tức & Sự kiện
Thư viện ảnh
Thư viện video
Copyright © 2014 ICTV. All Rights Reserved.
tư vấn iso, tu van iso, kiểm toán năng lượng, kiem toan nang luong