1. What are harmonics?

Harmonic components affect power quality and warrant investigation when distortion exceeds the applicable limits. Their frequencies are integer multiples of the fundamental frequency; for example, 250 Hz is the fifth harmonic in a 50 Hz system.

Harmonic currents can increase losses and heating and can affect equipment performance. Their impact depends on the harmonic spectrum, loading and the electrical system.

2. Effects of harmonics

Harmonics may cause cables to overheat and insulation to deteriorate. Motors may overheat, generate noise or experience torque pulsations, mechanical resonance and vibration. Capacitors may overheat and suffer dielectric damage. Lighting or displays may flicker, protection may trip unexpectedly, computers and networks may malfunction, and measurements may be affected.

3. How are harmonics generated?

Nonlinear loads draw nonsinusoidal current, introducing harmonics into the distribution system. Examples include power-electronic motor starters and drives, computers and other electronic equipment, electronic lighting and welding power supplies.

4. Harmonic mitigation

  • Use suitably designed harmonic filters.
  • Review load arrangement and equipment selection to reduce harmonic injection into the supply.

Discuss harmonic measurement with ITVC

Call ITVC to discuss your needs and a suitable service approach.

Call for quotation: 0914 564 579

5. ITVC measurement services

ITVC Global provides harmonic measurement and analysis for factory electrical systems.

  1. Conduct a preliminary review of the electrical system.
  2. Prepare the measurement plan, personnel and equipment.
  3. Measure harmonics at the facility.
  4. Collect and process the data.
  5. Prepare the report.

Example measurement results

Recorded harmonic data, logged at 15-second intervals.
Recorded harmonic data, logged at 15-second intervals.
Harmonic magnitude plots showing 63 components for voltage and current.
Harmonic magnitude plots showing 63 components for voltage and current.
Harmonic phase-angle display covering 63 components.
Harmonic phase-angle display covering 63 components.

Measurement parameters and scope

  • Continuously record current, voltage, power and power factor over an agreed period, store the data and analyse the results. The source describes logging at 1-second intervals for shorter studies or 15-second intervals for longer studies, depending on instrument configuration.
  • Measure harmonics on individual branches and across the factory network, identify contributing equipment and recommend mitigation measures.

Personnel and equipment

  • Personnel: energy auditors and engineers specialising in industrial electrical systems.
  • Equipment: multifunction electrical power and energy analysers.

ITVC GLOBAL · SERVICE ENQUIRIES

Discuss harmonic measurement with ITVC

Share your requirements and preferred timing. ITVC will review your enquiry and discuss a suitable service scope.

Send a service request →

Call for quotation: 0914 564 579
Ho Chi Minh City: 0859 553 986
Email: itvc.haiphong@itvc-global.com

Head office: 6th Floor, 22 Ly Tu Trong, Hong Bang Ward, Hai Phong, Vietnam.

 



Copyright © 2014 ICTV. All Rights Reserved.

tư vấn iso, tu van iso, kiểm toán năng lượng, kiem toan nang luong

0914 564 579